Honda CR-V: Recirculation Control Motor Circuit Troubleshooting

1. Check the No. 36 (10 A) fuse in the under-dash fuse/ relay box.

Is the fuse OK? YES-Go to step 2.

NO-Replace the fuse, and recheck. If the fuse blows again, check for a short in the No. 36 (10 A) fuse circuit.

2. Disconnect the recirculation control motor 7P connector.

3. Turn the ignition switch ON (II).

4. Measure the voltage between the recirculation control motor 7P connector terminal NO.1 and body ground.

Honda CR-V. HVAC (Heating, Ventilation, and Air Conditioning)

Is there battery voltage? YES-Go to step 5.

NO-Repair open in the wire between the No. 36 (10 A) fuse in the under-dash fuse/relay box and the recirculation control motor.

5. Turn the ignition switch OFF.

6. Test the recirculation control motor.

Is the recirculation control motor OK? YES-Go to step 7.

NO-Replace the recirculation control motor, or repair the recirculation control linkage or door.

7. Disconnect the HVAC control unit 28P connector.

8. Check for continuity between body ground and the HVAC control unit 28P connector terminals No. 21 and No. 22 individually.

Honda CR-V. HVAC (Heating, Ventilation, and Air Conditioning)

Is there continuity? YES-Repair short to body ground in the wire(s) between the HVAC control unit and the recirculation control motor.

NO-Go to step 9.

9. Turn the ignition switch ON (II), and check the same terminals for voltage to body ground.

Honda CR-V. HVAC (Heating, Ventilation, and Air Conditioning)

Is there any voltage? YES-Repair short to power in the wire(s) between the HVAC control unit and the recirculation control motor. This short may also damage the HVAC control unit. Repair the short to power before replacing the HVAC control unit.

NO-Go to step 10.

10. Turn the ignition switch OFF.

11. Check for continuity between the following terminals of the HVAC control unit 28P connector and the recirculation control motor 7P connector.

28P:
No.21
No.22

7P:
No.7
No.5

Honda CR-V. HVAC (Heating, Ventilation, and Air Conditioning)

Is there continuity? YES-Check for loose wires or poor connections at the HVAC control unit 28P connector and at the recirculation control motor 7P connector. If the connections are good, substitute a known-good HVAC control unit, and recheck. If the symptom/ indication goes away, replace the original HVAC control unit.

NO-Repair open in the wire(s) between the HVAC control unit and the recirculation control motor.

HVAC Control Power and Ground Circuit Troubleshooting

1. Check the No. 36 (10 A) fuse in the under-dash fuse/ relay box.

Is the fuse OK? YES-Go to step 2.

NO-Replace the fuse, and recheck. If the fuse blows again, check for a short in the No. 36 (10 A) fuse circuit.

2. Disconnect the HVAC control unit 28P connector.

3. Turn the ignition switch ON (II).

4. Measure the voltage between the HVAC control unit 28P connector terminal No. 27 and body ground.

Honda CR-V. HVAC (Heating, Ventilation, and Air Conditioning)

Is there battery voltage? YES-Go to step 5.

NO-Repair open in the wire between the No. 36 (10 A) fuse in the under-dash fuse/relay box and the HVAC control unit.

5. Turn the ignition switch OFF.

6. Check for continuity between the HVAC control unit 28P connector terminal No. 18 and body ground.

Honda CR-V. HVAC (Heating, Ventilation, and Air Conditioning)

Is there continuity? YES-Check for loose wires or poor connections at the HVAC control unit 28P connector. If the connections are good, substitute a known-good HVAC control unit, and recheck.

NO-Check for an open in the wire between the HVAC control unit and body ground. If the wire is OK, check for poor ground at G503.

READ NEXT:

 Radiator and A/C Condenser Fan Low Speed Circuit Troubleshooting

NOTE: Do not use this troubleshooting procedure if the A/C compressor is inoperative. Refer to the symptom troubleshooting index. Before doing symptom troubleshooting, check for powertrain DTCs.

 A/C Condenser Fan High Speed Circuit Troubleshooting

NOTE: Do not use this troubleshooting procedure if the radiator fan and/or A/C compressor is inoperative. Refer to the symptom troubleshooting index. Before doing symptom troubleshooting, check

 A/C Signal Circuit Troubleshooting

NOTE: Use this troubleshooting procedure if the A/C compressor, the A/C condenser fan, and radiator fan are inoperative. Before doing symptom troubleshooting, check for and resolve any powertrai

SEE MORE:

 Instrument Panel Brightness

You can change the instrument panel brightness only when the light switch is on. Turn the knob on the lower part of the instrument panel to adjust the brightness. You will hear a beep when maximum or minimum brightness is reached. To reduce glare at night, the instrument panel

 Differential Reassembly

Exploded View Special Tools Required Holder handle 07JAB-001020A Companion flange holder 07RAB-TB4010B 1. Apply differential fluid to the rubber pinion of the ATF strainer (A), then install the ATF strainer, the magnet (B), the dowel pins (C), and the oil pump pin (D), in the differential carri

© 2016-2025 Copyright www.hcrv.net